How can I troubleshoot the "Runtime.InvalidEntrypoint" error for my Lambda function that's from a Docker image?
Last updated: 2023-03-08
I received a "Runtime.InvalidEntrypoint" error when trying to create an AWS Lambda function from a Docker image.
Resolution
When the entry in the Lambda function configuration is incorrect, you receive the "Runtime.InvalidEntrypoint". To resolve this issue, check the following configuration settings for your Lambda function.
- Verify that the ENTRYPOINT and CMD to your container image include the absolute path as the location and doesn't contain a symlink as the ENTRYPOINT. For more information, see Container: Error occurs on runtime InvalidEntrypoint.
- Make sure that the ENTRYPOINT is correct in the Lambda function's configuration. Also, the ENTRYPOINT must match the command in the container's Dockerfile that's used for the runtime.
- Verify that the container image is pushed to the correct Amazon Elastic Container Registry (Amazon ECR).
- Make sure that the Docker image's architecture and the Lambda function are same. Lambda supports arm64 and x86_64 instruction set architectures.
- When the Lambda deployment package doesn't have the correct security permissions, you receive a "permission denied" error along with the "Runtime.InvalidEntrypoint" error occurs. In Unix permissions symbolic notation (from Wikipedia), 644 is the correct permissions for all files within a Lambda deployment package. For folders within a deployment package, the correct permissions setting is 755. For more information, see How do I troubleshoot "permission denied" or "unable to import module" errors when uploading a Lambda deployment package?